Schneider Electric LC2K1210K7 LC2K Series Reversing Contactor, 100 V AC v coil, 12 to 20 A, 3NO contact, 3 poles
Sku #38911805064
MFG #LC2K1210K7
Attributes
| Type: | Reversing Contactor |
| Coil Voltage: | 100 V AC |
| Number of Poles: | 3 |
| Series: | LC2K Series |
| Maximum Load Current: | 12 to 20 A |
| Frequency Rating: | 50/60 Hz |
- TeSys K contactors and overload relays are ideal for general duty applications where small size and reliability are key concerns
- A The special armature structure design allows all devices and all operating coils, either AC or DC, to have the same physical size and panel footprint for convenience
- Devices are available with low consumption DC operating coils for direct connection to PLC circuits
- Motor controlResistive load contactor application
- Preassembled with reversing power busbar device presentation
- 8 kV uimp rated impulse withstand voltage
- III overvoltage category
- 115 A 122 deg F (50 deg C) - 1 s power circuit105 A 122 deg F (50 deg C) - 5 s power circuit100 A 122 deg F (50 deg C) - 10 s power circuit75 A 122 deg F (50 deg C) - 30 s power circuit55 A 122 deg F (50 deg C) - 1 min power circuit50 A 122 deg F (50 deg C) - 3 min power circuit80 A - 1 s signalling circuit90 A - 500 ms signalling circuit110 A - 100 ms signalling circuit25 A 122 deg F (50 deg C) - >= 15 min power circuit icw rated short-time withstand current
- 3 mOhm - Ith 20 A 50 Hz power circuit average impedance
- Power circuit 600 V UL 508Power circuit 690 V IEC 60947-4-1Signalling circuit 690 V IEC 60947-4-1Signalling circuit 690 V IEC 60947-5-1Signalling circuit 600 V UL 508Power circuit 600 V CSA C22.2 No 14Signalling circuit 600 V CSA C22.2 No 14 ui rated insulation voltage
- Mechanical interlocking type
- 10 to 20 ms coil energisation and NO closing10 to 20 ms coil de-energisation and NO opening operating time
- B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1 safety reliability level
- 5 Mcycles mechanical durability
- <= 400 Hz signalling circuit frequency
- 02 in (0.5 mm) non overlap distance
- TC IEC 60068TC DIN 50016 protective treatment
- 6561.68 ft (2000 m) without derating operating altitude
- V1 conforming to UL 94Requirement 2 conforming to NF F 16-101Requirement 2 conforming to NF F 16-102 flame retardance
- Shocks contactor closed, on X axis10 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on Y axis15 Gn for 11 ms IEC 60068-2-27Shocks contactor closed, on Z axis15 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on X axis6 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on Y axis10 Gn for 11 ms IEC 60068-2-27Shocks contactor opened, on Z axis10 Gn for 11 ms IEC 60068-2-27Vibrations contactor closed4 Gn, 5 to 300 Hz IEC 60068-2-6Vibrations contactor opened2 Gn, 5 to 300 Hz IEC 60068-2-6 mechanical robustness
- Motor control,Resistive load,Control
- BS 5424|VDE 0660|NF C 63-110|IEC 60947|UL Listed|CSA|PROP65: Cancer - www.P65Warnings.ca.gov|UL CSA BS 5424 VDE 0660 NF C 63-110 IEC 60947